End-of-Season Watermaker Winterization
Before lay-up — watermaker checklist
Switching off the watermaker at season end is not enough. Per Seacraft FAQ, if the unit will be unused for more than 4 weeks, winterisation is required to prevent bacterial growth inside the membranes. This checklist is applied just before marina or ashore lay-up.
For flush and preservative details see the Membrane Flush & Winterization Guide; for spring opening see the Pre-Season Checklist. Chemical dosing and sequence are confirmed during service based on your model.
6-Step Summary
- Final freshwater flush (15 min)
- Drain system
- Preservative / lay-up chemical
- Remove filters
- Isolate power
- Book winter service
When Does This Checklist Apply?
| Situation | Winterisation needed? | Notes |
|---|---|---|
| Season end — boat wintering | Yes | Full checklist; Bodrum/Göcek package — book from October |
| Marina/ashore idle more than 4 weeks | Yes | FAQ threshold |
| 1–3 week break (active season) | No — not full winterisation | Extended flush enough — flush guide |
| Occasional winter use | Yes if idle exceeds 4 weeks | Repeat steps after last use |
Bodrum and Göcek location pages reference an active season of April–October; end-of-season care is typically planned as that period closes.
Step-by-Step End-of-Season Checklist
Items below match the existing checklist. Complete the final production run before starting; lay-up chemical application is best done with service support.
Final freshwater flush (~15 min)
After the last production of the season, rinse the membrane circuit with fresh water for about 15 minutes. Reduces salt build-up and leaves a clean path before lay-up — longer than routine post-run flush — flush guide.
Stop and drain the system
Stop production and depressurise safely. SCW series protection shuts down on sudden pressure loss — controlled shutdown is preferred at season end. Final check of leaks and pressure lines.
Apply preservative (pickle / lay-up chemical)
Circulate lay-up solution to protect the membrane over winter. Lay-up chemical is listed in the spare parts catalogue. Skipping end-of-season pickling is a common first-time mistake — common mistakes.
Remove pre-filters
Remove sediment and dolomite filters or replace them as part of the end-of-season package. Stored wet filters risk biological fouling. Bodrum/Göcek annual packages include on-site filter replacement.
Isolate power
Isolate DC/AC feeds per unit instructions. Align with your general boat electrical lay-up plan; check panel and remote connections for loose contacts after a season of vibration and moisture.
Book winter service
Especially for wintering boats, booking from October is recommended — Bodrum and Göcek FAQs. Service may include membrane cleaning, filters, lay-up and 250-hour pump oil assessment; scope confirmed after survey.
Plan spring opening now
After lay-up, apply the pre-season checklist in spring: drain preservative, fit new filters, test run and TDS check. The two checklists are sequential companions.
On-Site End-of-Season Package
Bodrum
An annual maintenance package for wintering boats includes end-of-season membrane cleaning, filter replacement and system winterisation on-site. Booking from October is recommended — Bodrum location.
Göcek
The same framework applies in Göcek; D-Marin Göcek offers long-term berthing and winter storage infrastructure. Book via Göcek location.
Didim and other marinas
Didim is described as a year-round wintering hub; watermaker work can be coordinated with general boat maintenance. Marmaris, Foça and other locations recommend annual on-site filter and membrane checks — all locations.
Spare parts readiness
Lay-up chemical, filters and pump oil if needed are supplied from the spare parts catalogue. Local manufacturing means parts are usually available within the same week — replacement schedule.
Owner vs Service — Who Does What?
| Task | Owner | Seacraft service |
|---|---|---|
| Final fresh-water flush | Possible | Included in package |
| System drain | With instructions | Recommended |
| Lay-up chemical | Experience needed | Recommended — model-specific dosing |
| Filter removal / change | Possible | Bodrum/Göcek package |
| Membrane cleaning / test | — | Annual package |
| 250-hour pump oil | Track hours — digital display | Change during service — FAQ |
Frequently Asked Questions
Related Guides
Membrane Flush & Winterization · Pre-Season Checklist · Watermaker Maintenance Guide · Spare Parts Schedule · All Guides
Plan End-of-Season Lay-Up On Site
Membrane cleaning, filters and preservative — one appointment
Book an Appointment Call: +90 252 412 90 78